Comparison between flapless-guided and conventional surgery for implant placement: a 12-month randomized clinical trial.
Informações
Título
Comparison between flapless-guided and conventional surgery for implant placement: a 12-month randomized clinical trial.
Título (EN)
Comparison between flapless-guided and conventional surgery for implant placement: a 12-month randomized clinical trial.
Autor(es)
Lucas Massaru Nomiyama, Edson Ken Matumoto, Mônica Grazieli Corrêa, Fabiano Ribeiro Cirano, Fernanda Vieira Ribeiro, Suzana Peres Pimentel, Marcio Zaffalon Casati.
Instituição
Universidade Paulista
Tipo
Artigo
Publicado em
Clin Oral Investig. 2023 Apr;27(4):1665-1679. doi: 10.1007/s00784-022-04793-3. Epub 2022 Nov 19.
Erratum in
Correction to: Comparison between flapless‑guided and conventional surgery for implant placement: a 12‑month randomized clinical trial.
Nomiyama LM, Matumoto EK, Corrêa MG, Cirano FR, Ribeiro FV, Pimentel SP, Casati MZ.
Clin Oral Investig. 2023 Jun;27(6):3285. doi: 10.1007/s00784-023-05045-8.
Resumo (EN)
Objectives: The study was aimed at comparing implants installed with guided and conventional surgery.
Material and methods: Twenty-nine total edentulous patients were selected, and maxillary contralateral quadrants were randomly assigned to static computer-aided implant surgery (S-CAIS): flapless computer-guided surgery, and conventional surgery (CS): flap surgery with conventional planning. Tomography scans were performed at baseline and 10 days after the surgery for deviation measurement, and radiography was done at baseline and after 6 and 12 months, for peri-implant bone level (PIBL) analysis. Peri-implant fluid and subgingival biofilm were collected to evaluate bone markers and periodontal pathogens.
Results: S-CAIS showed less linear deviation at the apical point and the midpoint and less angular deviation (p < 0.05), with greater depth discrepancy in the positioning of the platform (p < 0.05). Higher values of vertical PIBL were observed for the S-CAIS group at baseline (p < 0.05), while lower values of horizontal PIBL were observed for CS (p < 0.05). Bone markers and Tf presented higher levels in CS (p < 0.05). Flapless S-CAIS allowed smaller linear and angular deviations than the conventional technique.
Conclusion: However, PIBL was higher in S-CAIS; the conventional technique led to a greater angiogenic and bone remodeling activity by elevating the angiogenic levels and bone markers.
Clinical relevance: Evaluating the different implant insertion techniques can guide clinical and surgical regarding the accuracy, the release pattern of bone markers, and the peri-implant bone level.
Trial registration: ReBEC-RBR-8556fzp.
Palavras-chave
Clinical trial; Computer-assisted surgery; Dental implant; Patient-centered outcomes.
Direito de Acesso
Acesso restrito