Avaliação das densidades óticas de filmes radiográficos digitalizados quando processados pelo método roller
Title
Optical densities evaluation of digitized radiographic films assessed from roller processing
Autor(es)
Claudio Costa | Carla Mayumi Yamamoto | José Barbosa | Cíntia Helena Coury Saraceni | Paschoal Laércio Armonia
Edição
OUTUBRO/DEZEMBRO DE 2007
Curso
Odontologia
Palavras-chave
Filme para raios X; Radiografia dentária
Resumo (EN)
Introduction – The authors compared optical densities from four radiographic films: Ultraspeed, D, E and Insight (Eastman Kodak Company, Rochester, USA) using roller automatic processing. Material and Methods – Films were processed automatically using the AT2000 machine with normal speed. Comparative analysis was performed to evaluate optical density value to each film after processing. Results – Higher medium optical density values were found to D (213.16) and E (214.49) films and the lower one to Insight (198.37). Conclusion – D and Ultraspeed films presented remarkable differences to optical density.
Resumo
Introdução – Os autores compararam as densidades óticas de quatro filmes radiográficos: Ultra-speed; D; E e Insight (Eastman Kodak Company, Rochester, E.U.A.) utilizando-se o processamento automático roller. Material e Métodos – Os filmes foram processados automaticamente utilizando-se o equipamento AT2000 com velocidade normal. Análise comparativa foi realizada para avaliar a densidade ótica para cada filme após o processamento. Resultados – Os maiores valores médios de densidades óticas foram encontradas nos filmes D (213,16) e E (214,49) e o menor para o Insight (198,37). Conclusão – Os filmes D e Ultra-speed apresentaram diferenças marcantes de densidade ótica.